Single Phase String Inverter SUN-3.6/4/4.2/4.6/5/5.2/6/6.2K-G04P1-EU-P1
Single Phase String Inverter SUN-3.6/4/4.2/4.6/5/5.2/6/6.2K-G04P1-EU-P1

Single Phase String Inverter SUN-3.6/4/4.2/4.6/5/5.2/6/6.2K-G04P1-EU-P1

● 2 MPP trackers, Max. efficiency up to 97.5%
● Zero export application, VSG application
● String intelligent monitoring (optional)
● Wide output voltage range
● Anti-PID function (Optional)
● Low start-up voltage of 80V

Detail

Model SUN-3.6K-G04P1
-EU-AM2-P1
SUN-4K-G04P1
-EU-AM2-P1
SUN-4.2K-G04P1
-EU-AM2-P1
SUN-4.6K-G04P1
-EU-AM2-P1
SUN-5K-G04P1
-EU-AM2-P1
SUN-5.2K-G04P1
-EU-AM2-P1
SUN-6K-G04P1
-EU-AM2-P1
SUN-6.2K-G04P1
-EU-AM2-P1
Input Side
Max. DC Input Power (kW) 4.7 5.2 5.46 5.98 6.5 6.76 7.8 8.06
Max. DC Input Voltage (V) 550
Start-up DC Input Voltage (V) 80
MPPT Operating Range (V) 70-500
Max. DC Input Current (A) 18+18
Max. Short Circuit Current (A) 27+27
No.of MPP Trackers 2
No.of Strings per MPP Tracker 1+1
Output Side
Rated Output Power (kW) 3.6 4 4.2 4.6 5 5.2 6 6.2
Max. Active Power (kW) 3.96 4.4 4.62 5.06 5.5 5.72 6.6 6.82
Rated Output Voltage/Range (V) L/N/PE 220/230V (Optional) 0.85Un-1.1Un (this may vary with grid standards)
Rated Grid Frequency (Hz) 50 / 60 (Optional)
Operating Phase Single Phase
Rated AC Grid Output Current (A) 16.4/15.7 18.2/17.4 19.1/18.3 21/20 22.8/21.8 23.7/22.7 27.3/26.1 28.2/27
Max. AC Output Current (A) 18/17.3 20/19.2 21/20.1 23/22 25/24 26/24.9 30/28.7 31/29.7
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Harmonics Current Distortion (THDi) <3%
DC Injection Current (mA) <0.5%
Grid Frequency Range 45-55 or 55-65 (Optional)
Efficiency
Max. Efficiency 97.3% 97.5%
Euro Efficiency 97.5%
MPPT Efficiency >99%
Protection
DC Reverse-Polarity Protection Yes
AC Short Circuit Protection Yes
AC Output Overcurrent Protection Yes
Output Overvoltage Protection Yes
Insulation Resistance Protection Yes
Ground Fault Monitoring Yes
Anti-islanding Protection Yes
Temperature Protection Yes
Integrated DC Switch Yes
Remote Software Upload Yes
Remote Change of Operating Parameters Yes
Surge Protection DC Type II / AC Type II
General Data
Cabinet Size (WxHxD mm) 330×323×190 (Excluding Connectors and Brackets)
Weight (kg) 8
Topology Transformerless
Internal Consumption <1W (Night)
Running Temperature -25 to +65℃, >45℃ Derating
Ingress Protection IP65
Noise Emission (Typical) ≤35 dB
Cooling Concept Free Cooling
Permissible Altitude (m) 2000
Warranty 5 Years
Grid Connection Standard IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE-AR-N 4105
Operating Surroundings Humidity 0-100%
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Features
Display LCD1602
Interface RS485/RS232/Wifi/LAN