Three Phase String Inverter(LV) SUN-10K-G03-LV SUN-12/15K-G02-LV SUN-10/12/15/18/20/21K-G04-LV
Three Phase String Inverter(LV) SUN-10K-G03-LV SUN-12/15K-G02-LV SUN-10/12/15/18/20/21K-G04-LV

Three Phase String Inverter(LV) SUN-10K-G03-LV SUN-12/15K-G02-LV SUN-10/12/15/18/20/21K-G04-LV

● 120V/208V, 127V/220V, 133V/230V and 50/60Hz, Three phase system
● 2 MPP trackers, Max. efficiency up to 98.6%
● Zero export application, VSG application
● String intelligent monitoring (optional)
● Wide output voltage range
● Anti-PID function (Optional)

Detail

Model SUN-10K
-G03-LV
SUN-12K
-G02-LV
SUN-15K
-G02-LV
SUN-10K
-G04-LV
SUN-12K
-G04-LV
SUN-15K
-G04-LV
SUN-18K
-G04-LV
SUN-20K
-G04-LV
SUN-21K
-G04-LV
Input Side
Max. DC Input Power (kW) 13 15.6 19.5 13 15.6 19.5 23.4 26 27.3
Max. DC Input Voltage (V) 800
Start-up DC Input Voltage (V) 250
MPPT Operating Range (V) 200-700
Max. DC Input Current (A) 32+32 32+32 40+40
Max. Short Circuit Current (A) 48+48 48+48 60+60
No.of MPP Trackers 2 2 2
No.of Strings per MPP Tracker 3+3 2+2 3+3
Output Side
Rated Output Power (kW) 10 12 15 10 12 15 18 20 21
Max. Active Power (kW) 11 13.2 16.5 10 12 15 18 20 21
Rated Output Voltage/Range (V) 3L/N/PE 127V/220V 0.85Un-1.1Un
(this may vary with grid standards)
3L/N/PE 120V/208V, 127V/220V, 133V/230V
0.85Un-1.1Un (this may vary with grid standards)
Rated Grid Frequency (Hz) 60 50/60
Operating Phase Three Phase
Rated AC Grid Output Current (A) 26.2 31.5 39.4 27.8/26.3/25.1 33.4/31.5/30.1 41.7/39.4/37.6 50/47.3/45.2 55.6/52.5/50.2 58.4/55.2/52.7
Max. AC Output Current (A) 28.9 34.6 43.3 27.8/26.3/25.1 33.4/31.5/30.1 41.7/39.4/37.6 50/47.3/45.2 55.6/52.5/50.2 58.4/55.2/52.7
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Harmonics Current Distortion (THDi) <3%
DC Injection Current (mA) <0.5%
Efficiency
Max. Efficiency 98.6%
Euro Efficiency 98%
MPPT Efficiency >99%
Protection
DC Reverse-Polarity Protection Yes
AC Short Circuit Protection Yes
AC Output Overcurrent Protection Yes
Output Overvoltage Protection Yes
Insulation Resistance Protection Yes
Ground Fault Monitoring Yes
Anti-islanding Protection Yes
Temperature Protection Yes
Integrated DC Switch Yes
Remote Software Upload Yes
Remote Change of Operating Parameters Yes
Surge Protection DC Type II / AC Type II
General Data
Cabinet Size (WxHxD mm) 362×577×215 (Excluding Connectors and Brackets)
Weight (kg) 23
Topology Transformerless
Internal Consumption <1W (Night)
Running Temperature -25 to +65℃, >45℃ Derating
Ingress Protection IP65
Noise Emission (Typical) ≤40 dB ≤50 dB
Cooling Concept Smart Cooling
Permissible Altitude (m) 2000
Warranty 5 Years
Grid Connection Standard NBR 16149, NBR 16150, EN 50549, RD 140
Operating Surroundings Humidity 0-****
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Features
Display LCD1602
Interface RS485/RS232/Wifi/LAN