Three Phase String Inverter(LV) SUN-10/12/15K-G05-LV
Three Phase String Inverter(LV) SUN-10/12/15K-G05-LV

Three Phase String Inverter(LV) SUN-10/12/15K-G05-LV

● 120V/208V, 127V/220V, 133V/230V and 50/60Hz, Three phase system
● 2 MPP trackers, Max. efficiency up to 98.6%
● Zero export application, VSG application
● String intelligent monitoring (optional)
● Wide output voltage range
● Anti-PID function (Optional)

Detail

Model SUN-10K-G05-LV SUN-12K-G05-LV SUN-15K-G05-LV
Input Side
Max. DC Input Power (kW) 13 15.6 19.5
Max. DC Input Voltage (V) 800
Start-up DC Input Voltage (V) 250
MPPT Operating Range (V) 200-700
Max. DC Input Current (A) 26+26
Max. Short Circuit Current (A) 39+39
No.of MPP Trackers 2
No.of Strings per MPP Tracker 2
Output Side
Rated Output Power (kW) 10 12 15
Max. Active Power (kW) 10 12 15
Rated Output Voltage/Range (V) 3L/N/PE 120V/208V, 127V/220V, 133V/230V 0.85UN-1.1UN
Rated Grid Frequency (Hz) 50/60
Operating Phase Three Phase
Rated AC Grid Output Current (A) 27.8/26.3/25.1 33.4/31.5/30.1 41.7/39.4/37.6
Max. AC Output Current (A) 27.8/26.3/25.1 33.4/31.5/30.1 41.7/39.4/37.6
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Harmonics Current Distortion (THDi) <3%
DC Injection Current (mA) <0.5%
Grid Frequency Range 57-62
Efficiency
Max. Efficiency 98.6%
Euro Efficiency 98%
MPPT Efficiency >99%
Protection
DC Reverse-Polarity Protection Yes
AC Short Circuit Protection Yes
AC Output Overcurrent Protection Yes
Output Overvoltage Protection Yes
Insulation Resistance Protection Yes
Ground Fault Monitoring Yes
Anti-islanding Protection Yes
Temperature Protection Yes
Integrated DC Switch Yes
Remote Software Upload Yes
Remote Change of Operating Parameters Yes
Surge Protection DC Type II / AC Type II
General Data
Cabinet Size (WxHxD mm) 362W×527H×220D (Excluding connectors and brackets)
Weight (kg) 20
Topology Transformerless
Internal Consumption <1W (Night)
Running Temperature -25 to +60℃, >45℃ Derating
Ingress Protection IP65
Noise Emission (Typical) ≤50 dB
Cooling Concept Smart Cooling
Permissible Altitude (m) 4000m
Warranty 5 Years
Grid Connection Standard NBR 16149, NBR 16150, EN 50549, RD 140
Operating Surroundings Humidity 0-100%
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Features
Display LCD1602
Interface RS485/RS232/Wifi/LAN