Hybrid Inverter SUN-3.6/5/6K-SG03LP1-EU-AM2-P1
Hybrid Inverter SUN-3.6/5/6K-SG03LP1-EU-AM2-P1

Hybrid Inverter SUN-3.6/5/6K-SG03LP1-EU-AM2-P1

● Colorful touch LCD, IP65 protection degree
● Max. charging/discharging current of 135A
● Support storing energy from diesel generator
● Max. 16 pcs parallel for on-grid and off-grid
● operation; Support multiple batteries parallel
● AC couple to retrofit existing solar system
● 6 time periods for battery charging/discharging

Detail

Model SUN-3.6K-SG03LP1-EU-AM2-P1 SUN-5K-SG03LP1-EU-AM2-P1 SUN-6K-SG03LP1-EU-AM2-P1
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 90 120 135
Max. Discharging Current (A) 90 120 135
External Temperature Sensor Yes
Charging Curve 3 Stages / Equalization
Charging Strategy for Li-Ion Battery Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W) 4680 6500 7800
Rated PV Input Voltage (V) 370 (125-500)
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Full Load DC Voltage Range (V) 250-425
PV Input Current (A) 18+18
Max. PV IS C (A) 27+27
No.of MPP Trackers 2
No.of Strings per MPP Tracker 1+1
AC Output Data
Rated AC Output Active Power (W) 3600 5000 6000
Max. AC OutputActive Power (W) 3960 5500 6600
AC Output Rated Current (A) 16.4/15.7 22.8/21.8 27.3/26.1
Max. AC Output Current (A) 18/17.2 18/17.2 25/24 30/28.7
Max. Continuous AC Passthrough (A) 35 40
Peak Power (off grid) 2 time of rated power, 10 S
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Power Factor 1
Output Frequency and Voltage 50/60Hz; L/N/PE 220/230Vac
Grid Type Single Phase
Total Harmonics Current Distortion (THDi) <3% (of nominal power)
DC Current Injection <0.5% In
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 96.50%
MPPT Efficiency 99.90%
Protection
Integrated Anti-islanding Protection, PV String Input Reverse Polarity Protection,
Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection,
Output Shorted Protection, Surge Protection
Over Voltage Category DC Type II/AC Type III
Certifications and Standards
Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Cooling Free Cooling
Noise (dB) ≤30 dB
Communication with BMS RS485; CAN
Weight (kg) 20.5
Cabinet Size (WxHxD mm) 330×433×238 (Excluding Connectors and Brackets)
Protection Degree IP65
Installation Style Wall-mounted
Warranty 5 Years (10 Years Optional)