Hybrid Inverter SUN-3.6/5/6/7/7.6/8K-SG05LP1-EU
Hybrid Inverter SUN-3.6/5/6/7/7.6/8K-SG05LP1-EU

Hybrid Inverter SUN-3.6/5/6/7/7.6/8K-SG05LP1-EU

● Colorful touch LCD, IP65 protection degree
● Max. charging/discharging current of 190A
● Support storing energy from diesel generator
● Max. 16 pcs parallel for on-grid and off-grid
● operation; Support multiple batteries parallel
● AC couple to retrofit existing solar system
● 6 time periods for battery charging/discharging

Detail

Model SUN-3.6K
-SG05LP1-EU
SUN-5K
-SG05LP1-EU
SUN-6K
-SG05LP1-EU
SUN-7K
-SG05LP1-EU
SUN-7.6K
-SG05LP1-EU
SUN-8K
-SG05LP1-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 90 120 135 175 190 190
Max. Discharging Current (A) 90 120 135 175 190 190
External Temperature Sensor Yes
Charging Curve 3 Stages / Equalization
Charging Strategy for Li-Ion Battery Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W) 4680 6500 7800 10000 9880 10400
Rated PV Input Voltage (V) 370 (125-500)
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Full Load DC Voltage Range (V) 300-425 200-425
PV Input Current (A) 13+13 26+26
Max. PV IS C (A) 17+17 34+34
No.of MPP Trackers 2
No.of Strings per MPP Tracker 1+1 2+2
AC Output Data
Rated AC Output Active Power (W) 3600 5000 6000 7000 7600 8000
Max. AC OutputActive Power (W) 3960 5500 6600 7700 8360 8800
AC Output Rated Current (A) 16.4/15.7 22.7/21.7 27.3/26.1 31.9/30.5 34.5/33 36.4/34.8
Max. AC Output Current (A) 18/17.2 18/17.2 25/23.9 30/28.7 35/33.5 38/36.3 40/38.3
Max. Continuous AC Passthrough (A) 35 40 50
Peak Power (off grid) 2 time of rated power, 10 S
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Power Factor 1
Output Frequency and Voltage 50/60Hz; L/N/PE 220/230Vac
Grid Type Single Phase
Total Harmonics Current Distortion (THDi) <3% (of nominal power)
DC Current Injection <0.5% In
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 96.50%
MPPT Efficiency 99.90%
Protection
Integrated Anti-islanding Protection, PV String Input Reverse Polarity Protection,
Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection,
Output Shorted Protection, Surge Protection
Over Voltage Category DC Type II/AC Type III
Certifications and Standards
Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Cooling Smart Cooling
Noise (dB) ≤30 dB
Communication with BMS RS485; CAN
Weight (kg) 24
Cabinet Size (WxHxD mm) 330×580×232 (Excluding Connectors and Brackets)
Protection Degree IP65
Installation Style Wall-mounted
Warranty 5 Years (10 Years Optional)