Hybrid Inverter SUN-12/14/16K-SG01LP1-EU
Hybrid Inverter SUN-12/14/16K-SG01LP1-EU

Hybrid Inverter SUN-12/14/16K-SG01LP1-EU

● Colorful touch LCD, IP65 protection degree
● Max. charging/discharging current of 250A
● Support storing energy from diesel generator
● Max. 16 pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
● AC couple to retrofit existing solar system
● 6 time periods for battery charging/discharging

Detail

Model SUN-12K-SG01LP1-EU SUN-14K-SG01LP1-EU SUN-16K-SG01LP1-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 220 250 290
Max. Discharging Current (A) 220 250 290
External Temperature Sensor Yes
Charging Curve 3 Stages / Equalization
Charging Strategy for Li-Ion Battery Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W) 15600 18200 20800
Rated PV Input Voltage (V) 370
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Full Load DC Voltage Range (V) 500
PV Input Current (A) 26+26+26
Max. PV IS C (A) 44+44+44
No.of MPP Trackers 3
No.of Strings per MPP Tracker 2+2+2
AC Output Data
Rated AC Output Active Power (W) 12000 14000 16000
Max. AC OutputActive Power (W) 13200 15400 17600
AC Output Rated Current (A) 54.5/52.2 63.6/60.9 72.7/69.6
Max. AC Output Current (A) 18/17.2 60/57.4 70/67 80/76.5
Max. Continuous AC Passthrough (A) 100
Peak Power (off grid) 2 time of rated power, 10 S
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Power Factor 1
Output Frequency and Voltage 50/60Hz; L/N/PE 220/230Vac
Grid Type Single Phase
Total Harmonics Current Distortion (THDi) <3% (of nominal power)
DC Current Injection <0.5% In
Backup Data
Backup Power (W) 10000 12000 14000
Backup Rated Current (A) 45.5/43.5 54.5/52.2 63.6/60.9
Backup UPS 4ms Automatic switchover time
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 96.50%
MPPT Efficiency 99.90%
Protection
Integrated Anti-islanding Protection, PV String Input Reverse Polarity Protection,
Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection,
Output Shorted Protection, Surge Protection
Over Voltage Category DC Type II/AC Type III
Certifications and Standards
Grid Regulation IEC 61727, IEC 62116, AS 4777.2, NRS 097
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Cooling Free Cooling
Noise (dB) ≤30 dB
Communication with BMS RS485; CAN
Weight (kg) 48.5
Cabinet Size (WxHxD mm) 464×763×282 (Excluding Connectors and Brackets)
Protection Degree IP65
Installation Style Wall-mounted
Warranty 5 Years (10 Years Optional)