Three Phase Hybrid Inverter SUN-29.9/30/35K-SG01HP3-EU-BM3 SUN-40/50K-SG01HP3-EU-BM4
Three Phase Hybrid Inverter SUN-29.9/30/35K-SG01HP3-EU-BM3 SUN-40/50K-SG01HP3-EU-BM4

Three Phase Hybrid Inverter SUN-29.9/30/35K-SG01HP3-EU-BM3 SUN-40/50K-SG01HP3-EU-BM4

● 100% unbalanced output, each phase
● Max. charging/discharging current of 100A
● Support storing energy from diesel generator
● Max. 10 pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
● AC couple to retrofit existing solar system
● 6 time periods for battery charging/discharging
● High voltage battery, higher efficiency

Detail

Model SUN-29.9K-SG01HP3
-EU-BM3
SUN-30K-SG01HP3
-EU-BM3
SUN-35K-SG01HP3
-EU-BM3
SUN-40K-SG01HP3
-EU-BM4
SUN-50K-SG01HP3
-EU-BM4
Battery Input Data
Battery Type Lithium-ion
Battery Voltage Range (V) 160-800
Max. Charging Current (A) 50+50
Max. Discharging Current (A) 50+50
External Temperature Sensor 2
Number of Battery Input Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W) 38870 39000 45500 52000 65000
Max. DC Input Voltage (V) 1000
Start-up Voltage (V) 180
MPPT Range (V) 150-850
Full Load DC Voltage Range (V) 360-850 360-850 420-850 360-850 450-850
Rated DC Input Voltage (V) 600
PV Input Current (A) 36+36+36 36+36+36 36+36+36 36+36+36+36
Max. PV IS C (A) 55+55+55 55+55+55 55+55+55 55+55+55+55
No.of MPP Trackers 3 4
No.of Strings per MPP Tracker 2+2+2 2+2+2+2
AC Output Data
Rated AC Output Active Power (W) 29900 30000 35000 40000 50000
Max. AC OutputActive Power (W) 29900 33000 38500 44000 55000
AC Output Rated Current (A) 45.4/43.4 45.5/43.5 53.1/50.8 60.7/58 75.8/72.5
Max. AC Output Current (A) 45.4/43.4 50/47.8 58.4/55.8 66.7/63.8 83.4/79.7
Max. Three-phase Unbalanced Output Current (A) 60 60 60 70 83.3
Max. Continuous AC Passthrough (A) 200
Peak Power (off grid) 1.5 time of rated power, 10 S
Generator Input/Smart Load
/AC Couple Current (A)
45.4 / 200 / 45.4 45.5 / 200 / 45.5 53.1 / 200 / 53.1 60.7 / 200 / 60.7 75.8 / 200 / 75.8
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Output Frequency and Voltage 50/60Hz; 3L/N/PE 220/380, 230/400Vac
Grid Type Three Phase
Total Harmonics Current Distortion (THDi) <3% (of nominal power)
DC Current Injection <0.5% In
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 97.00%
MPPT Efficiency 99.90%
Protection
Integrated Anti-islanding Protection, PV String Input Reverse Polarity Protection,
Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection,
Output Shorted Protection, Surge Protection, Arc Fault Circuit Interruption (AFCI optional)
Over Voltage Category DC Type II/AC Type III
Certifications and Standards
Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Cooling Smart Cooling
Noise (dB) ≤65 dB
Communication with BMS CAN
Weight (kg) 80
Cabinet Size (WxHxD mm) 527×894×294 (Excluding Connectors and Brackets)
Protection Degree IP65
Installation Style Wall-mounted
Warranty 5 Years (10 Years Optional)