S6-EH1P(12-16)K-L (without screen)
S6-EH1P(12-16)K-L (without screen)
S6-EH1P(12-16)K-L (without screen)
S6-EH1P(12-16)K-L (without screen)
S6-EH1P(12-16)K-L (without screen)
S6-EH1P(12-16)K-L (without screen)
S6-EH1P(12-16)K-L (without screen)

S6-EH1P(12-16)K-L (without screen)

Detail

Features:

String current up to 20A, perfectly match large current modules

Built-in Backup Port with Automatic UPS switching

10 second 200% surge power backup overload capability

6 customisable charge/discharge time settings

Generator connectivity with multiple input methods and automatic generator On/Off control

Supports 1ph and 3ph flexible connection with max 96kW in parallel

Supports peak shaving control in both "self-use" and "generator" mode

Intelligent AC coupling scheme, easily upgrade existing grid-connected systems


Models:

S6-EH1P12K-L

S6-EH1P14K-L

S6-EH1P16K-L


DATASHEET

Models 12K 14K 16K
Input DC (PV side)
Recommended max. PV power 16.8 kW 19.6 kW 22.4 kW
Max. input voltage 550 V
Rated voltage 380 V
Start-up voltage 100 V
MPPT voltage range 80-520 V
Max. input current 40 A / 40 A / 40 A
Max. short circuit current 50 A / 50 A / 50 A
MPPT number/Max. input strings number 3/6
Battery
Battery type Li-ion / Lead-acid
Battery voltage range 40 - 60 V
Max. charge / discharge power 12 kW 14 kW 16 kW
Communication CAN/RS485
Output AC (Grid side)
Rated output power 12 kW 14 kW 16 kW
Max. apparent output power 12 kVA 14 kVA 16 kVA
Operation phase L/N/PE
Rated grid voltage 220 V / 230 V
Rated grid frequency 50 Hz / 60 Hz
Rated grid output current 54.5 A / 52.2 A 63.6 A / 60.9 A 72.7 A / 69.6 A
Max. output current 54.5 A / 52.2 A 63.6 A / 60.9 A 72.7 A / 69.6 A
Power factor 1.0
THDi <3%
Input AC (Grid side)
Input voltage range 187-253 V
Max. input current 110 A
Frequency range 45-55 HZ/55-65 HZ
Output AC (Back-up)
Rated output power 12 kW 14 kW 16 kW
Max. apparent output power 2 times of rated power, 10 S
Back-up switch time <4 ms
Rated output voltage L/N/PE, 220 V / 230 V
Rated frequency 50 Hz / 60 Hz
Rated output current 54.5 A / 52.2 A 63.6 A / 60.9 A 72.7 A / 69.6 A
Max. output over current protection, 10 sec 109 A 127 A 145 A
Max. Continuous AC Passthrough 100 A
THDv (@linear load) <3%
Max. number of parallel 10
Input Generator
Max. input power 12 kW 14 kW 16 kW
Max. input current 54.5 A 63.6 A 72.7 A
Rated input frequency 50 Hz / 60 Hz
Efficiency
Max. efficiency 97.6%
EU efficiency 97.2%
BAT charged by PV Max. efficiency > 94.9%
BAT charged/discharged to AC Max. efficiency > 94.33%/93.51%
Protection
Surge protection Yes
DC reverse-polarity protection Yes (PV only)
Ground fault monitoring Yes
Integrated AFCI (DC arc-fault circuit protection) Yes (1)
Protection class/Over voltage category I/II
General Data
Dimensions (W*H*D) 464*763*282 mm
Weight 48.5 kg
Topology Transformerless
Operating ambient temperature range -40 ~ +60°C
Ingress protection IP66
Cooling concept Intelligent redundant fan-cooling
Max. operation altitude 4000 m
Grid connection standard NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530
Safety/EMC standard IEC/EN 62109-1/-2, EN 61000-6-2/-3
Features
DC connection MC4 plug (PV port) / Terminal Block (BAT port)
AC connection Terminal Block
Interface LED indicator lights, Bluetooth/Phone app
Communication RS485, Optional: Wi-Fi, LAN