Solis Three Phase High Voltage Energy Storage Inverters
Integrated 4 MPPTs for multiple array orientations
Up to 50A max charge/discharge current
String current up to 20A, perfectly match large current modules
10 second 200% surge power backup overload capability
Supports Max 6 pcs in parallel
Supports Unbalanced and Half-Wave Loads on both the Grid and Backup Port
Supports peak shaving control in both "self-use" and "generator" mode
6 customisable charge/discharge time settings
Automatic UPS switching
Intelligent AC coupling scheme, easily upgrade existing grid-connected systems
S6-EH3P12K-H
S6-EH3P15K-H
S6-EH3P20K-H
Models | 12K | 15K | 20K |
Input DC (PV side) | |||
Recommended max. PV array size | 24 kW | 30 kW | 40 kW |
Max. usable PV input power | 19.2 kW | 24 kW | 32 kW |
Max. input voltage | 1000 V | ||
Rated voltage | 600 V | ||
Start-up voltage | 160 V | ||
MPPT voltage range | 200-850 V | ||
Max. input current | 20 A / 20 A / 20 A / 20 A | ||
Max. short circuit current | 30 A / 30 A / 30 A / 30 A | ||
Max. input power per MPPT | 9 kW | ||
MPPT number/Max. input strings number | 4/4 | ||
Battery | |||
Battery type | Li-ion | ||
Battery voltage range | 120-800 V | ||
Max. charge / discharge power | 12 kW | 15 kW | 20 kW |
Max. charge / discharge current | 50 A | ||
Communication | CAN/RS485 | ||
Output AC (Grid side) | |||
Rated output power | 12 kW | 15 kW | 20 kW |
Max. apparent output power | 12 kVA | 15 kVA | 20 kVA |
Rated grid voltage | 3/N/PE, 380 V / 400 V | ||
Rated grid frequency | 50 Hz / 60 Hz | ||
Rated grid output current | 18.2 A / 17.3 A | 22.8 A / 21.7 A | 30.4 A / 28.9 A |
Max. output current | 18.2 A / 17.3 A | 22.8 A / 21.7 A | 30.4 A / 28.9 A |
Power factor | >0.99 (0.8 leading - 0.8 lagging) | ||
THDi | <3% | ||
Input AC (Grid side) | |||
Max. input power | 18 kW | 22.5 kW | 30 kW |
Rated input current | 27.3 A / 26 A | 34.2 A / 32.5 A | 45.6 A / 43.3 A |
Rated input voltage | 3/N/PE, 380 V / 400 V | ||
Rated input frequency | 50 Hz / 60 Hz | ||
Output AC (Back-up) | |||
Rated output power | 12 kW | 15 kW | 20 kW |
Max. apparent output power | 2 times of rated power, 10 s | ||
Back-up switch time | <10 ms | ||
Rated output voltage | 3/N/PE, 380 V / 400 V | ||
Rated frequency | 50 Hz / 60 Hz | ||
Rated output current | 18.2 A / 17.3 A | 22.8 A / 21.7 A | 30.4 A / 28.9 A |
THDv (@linear load) | <3% | ||
Input Generator | |||
Max. input power | 12 kW | 15 kW | 20 kW |
Max. input current | 18.2 A / 17.3 A | 22.8 A / 21.7 A | 30.4 A / 28.9 A |
Rated input frequency | 50 Hz / 60 Hz | ||
Efficiency | |||
Max. efficiency | 98.5% | ||
EU efficiency | 97.5% | ||
BAT charged by PV Max. efficiency | 98.5% | ||
BAT charged/discharged to AC Max. efficiency | 97.5% | ||
Protection | |||
Anti-islanding protection | Yes | ||
Output over current protection | Yes | ||
Short circuit protection | Yes | ||
Integrated AFCI (DC arc-fault circuit protection) | Yes (1) | ||
Integrated DC switch | Yes | ||
DC reverse-polarity protection | Yes | ||
PV over voltage protection | Yes | ||
Battery reverse protection | Yes | ||
General Data | |||
Dimensions (W*H*D) | 563*546*235 mm | ||
Weight | TBD | ||
Topology | Transformerless | ||
Self-consumption (night) | <25 W | ||
Operating ambient temperature range | -25 ~ +60°C | ||
Relative humidity | 0-95% | ||
Ingress protection | IP66 | ||
Cooling concept | Intelligent redundant fan-cooling | ||
Max. operation altitude | 2000 m | ||
Grid connection standard | EN 50549-1, VDE4105 CEI 0-21, CEI 0-16, NC-RFG TypeB, NRS 097-2-1 ED 2.1 | ||
Safety/EMC standard | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-3, IEC 61000-2 | ||
Features | |||
PV connection | MC4 connector | ||
Battery connection | OT terminal | ||
AC connection | OT terminal | ||
Display | LED + Bluetooth + APP | ||
Communication | CAN, RS485, Ethernet, Optional: Wi-Fi, Cellular, LAN |